Northwest Manufacturing, Inc600 Polk Ave SWRed Lake Falls, MN 56750www.woodmaster.comRetain this manualOwners ManualManual PN: 7994-300Rev: 13.4
10Flex Fuel Owner’s Manual 20125: InstallationYour Flex fuel must be installed by a professional and should follow all local, state and federal laws a
112012 Flex Fuel Owner’s Manual5: Installation5.4 Water Connections The following layouts are basic conguration for the furnace water connections.
12Flex Fuel Owner’s Manual 20125: InstallationFurnace and Buer inseparate buildings running with a plate pump.Furnace and Buer inseparate buildings
132012 Flex Fuel Owner’s Manual5: InstallationPlumbing the Rear of the Furnace The images below show how to connect the pump to the back of your Flex
14Flex Fuel Owner’s Manual 20125: InstallationExpansion Tank Since the Flex fuel is a non pressurized system, an expansion tank is needed to allow th
152012 Flex Fuel Owner’s Manual5: InstallationExpansion Tank (20 Gallon Shown)0020-247 1” Blk St 900020-247 1” Blk St 900020-2501” x 2” Blk nipple0020
16Flex Fuel Owner’s Manual 20125: InstallationBuer Tank Kit (020-0009)Part No. Description0020-140 1” Pex x 1” MPT (2)0020-145 1” Pex Crimp Ring (
172012 Flex Fuel Owner’s Manual5.5 Electrical ConnectionsNote: Be sure to follow all local, state and federal guidelines. Wiring installation should b
18Flex Fuel Owner’s Manual 20125: Installation5.6 I/O BoardPellet AugerRoom Feed AugerVibratorLAMBDACIRC TempStack TempStove TempSupply TempReturn Tem
192012 Flex Fuel Owner’s Manual5: InstallationFlex fuel 60 kWFlex fuel 30 kW# 4Main Circulating Pump Connections
2Flex Fuel Owner’s Manual 2012Congratulations on your decision to purchase the WoodMaster Flex fuel. You will be extremely pleased with this product,
20Flex Fuel Owner’s Manual 20125: Installation5.7 Connecting to Heating SystemExisting Forced AirA water to air heat exchanger is inserted in the exis
212012 Flex Fuel Owner’s Manual6: FuelsAll fuels must conform to certain quality standards to ensure trouble free operation of the furnace. Use of una
22Flex Fuel Owner’s Manual 2012It is only possible to switch the furnace on and o from the start screen. The currently selectedoperating mode is indi
232012 Flex Fuel Owner’s Manual The furnace is then switched on and you are returned to the start screen. The status line indicates the current ope
24Flex Fuel Owner’s Manual 20128: DisplayOverview:All settings are changed using the Control Knob in the center of the operating unit. Turn the wheel
252012 Flex Fuel Owner’s Manual8: Display8.1 The Starting ScreenThe displayed values are current actual values. The boiler temperature, the ue gas te
26Flex Fuel Owner’s Manual 20128.2 Menu NavigationScrolling Through the System Components On the starting screen, turn the control knob to the right
272012 Flex Fuel Owner’s ManualChanging/Viewing Individual Settings By turning the control knob, you can: •Navigatebetweenvariousmainmenulev
28Flex Fuel Owner’s Manual 2012If you press the control knob on the starting screen, the menu “BASIC BOILER SETTINGS” will appear (Shown Below). Press
292012 Flex Fuel Owner’s Manual9.5 Setting the Clock/DateNote: There is no automatic conversion for daylight saving time.Note: This furnace runs on DD
32012 Flex Fuel Owner’s Manual1. Contents ...
30Flex Fuel Owner’s Manual 20129.8 Output Test – Heating CycleNote: Output tests may be preformed by the owner, however, damage can occur if preforme
312012 Flex Fuel Owner’s Manual Move the curser by turning the control knob to the output test – boiler line and press the control knob. The menu “
32Flex Fuel Owner’s Manual 20129.11 Hour MeterThe following operating hours are also logged: • Feedruntime(inhours) • Lambdasensorheatingtim
332012 Flex Fuel Owner’s Manual10.1 View of the Selected Operating Mode When booting up the display, the set operating mode is automatically displaye
34Flex Fuel Owner’s Manual 2012Depending on the installed options, up to three furnace operating modes are available: •Bulkmaterials The furnace
352012 Flex Fuel Owner’s Manual10: Operating ModesFLEX FUELV 10.060 Tu, 12.09.10Bulk materialsBoiler temperature:Flue gas temperature:Air factor:Boile
36Flex Fuel Owner’s Manual 2012Turn the control knob to move the cursor to the line of the desired operating mode. For example, the following picture
372012 Flex Fuel Owner’s ManualNote: Always ensure that the insert corresponding to the furnace operating mode is tted and the pellet slide and ap (
38Flex Fuel Owner’s Manual 2012Check the Insert Check that the correct insert is installed in the rebox, and that the insert is free from any buildu
392012 Flex Fuel Owner’s ManualFiringFirst take the dry, small-sized and easily combustible material and arrange it parallel to the rebox side wall u
4Flex Fuel Owner’s Manual 20121: Table of Contents11. Bulk Materials Mode ...
40Flex Fuel Owner’s Manual 2012Now close the rebox door and wait unit the status line changes from “Please ignite” to “Bulk materials”. This changeov
412012 Flex Fuel Owner’s ManualNow you can completely ll the rebox right to the top with bulk material for a full burn, or a part load, depending on
42Flex Fuel Owner’s Manual 201211.6 Status Lines During Furnace Operating Mode “Bulk materials”Boiler is switched o! The furnace is switched o. Pre
432012 Flex Fuel Owner’s ManualSmoldering gas extraction! Please add more! Smoldering gas extraction is activated. You can now add more bulk material
44Flex Fuel Owner’s Manual 2012 Before lling, it is recommended that the buer temperatures are checked. If the existing temperature is already su
452012 Flex Fuel Owner’s ManualNote: Always ensure that the insert corresponding to the furnace operating mode is tted and the pellet slide and ap (
46Flex Fuel Owner’s Manual 201212: Bulk Materials Auto ModeCheck the Status Line(s) Always monitor the current operating status which is displayed on
472012 Flex Fuel Owner’s ManualNext cover the small pieces with a layer of paper. Covered the paper with another small layer of bulk materials. Ensure
48Flex Fuel Owner’s Manual 2012Cover the cardboard with a layer of small bulk materi-als that covers the entire bottom of the rebox.12: Bulk Material
492012 Flex Fuel Owner’s Manual Then turn the control knob to scroll to the screen “BULK MATERIALS AUTO CONTROL“. The release mode currently set and
52012 Flex Fuel Owner’s Manual2: TermsFlex fuel - Hydronic heater designed to burn multiple wood fuel typesFurnace/Boiler AKA appliance, stove - An ap
50Flex Fuel Owner’s Manual 2012 You can now enter up to three release periods for the weekdays Monday to Friday. If furnace operating mode “Bulk ma
512012 Flex Fuel Owner’s ManualRelease Mode “acc. to date” Select release mode “acc. to date” if the furnace should be started on a particular day. T
52Flex Fuel Owner’s Manual 2012Note: Always ensure that the insert corresponding to the furnace operating mode is tted and the pellet slide and ap (
532012 Flex Fuel Owner’s ManualCheck Status Line(s) Before starting the furnace in “Pellets Auto control” the furnace should be switched o.Check Pel
54Flex Fuel Owner’s Manual 201213: Pellets Auto ControlAdjustment Bolt (Fig. 1) Correct Burn: no further adjustments needed (Fig. 2)Incorrect Burn: bo
552012 Flex Fuel Owner’s Manual13: Pellets Auto Control13.4 Starting the Furnace in Operating Mode “Pellets auto control”Setting the Furnace Operating
56Flex Fuel Owner’s Manual 201213.6 Status Lines for Operating Mode “Pellets auto control”Boiler is switched o! The furnace is switched o. If you w
572012 Flex Fuel Owner’s Manual13: Pellets Auto ControlPellets mode! Thefurnaceregulatesin“Pelletsmode!”aslongasthereisacallforheatand
58Flex Fuel Owner’s Manual 2012FGT-drop or AR too high! Fan lag! Theuegastemperatureduringthe“Startphase!”orin“Pelletsmode!”hasnoticeab
592012 Flex Fuel Owner’s Manual13: Pellets Auto ControlFeeder temperature too high! Fan lag! The temperature monitor in the feeder has measured an ov
6Flex Fuel Owner’s Manual 20122: TermsAir Ratio - See air factorESC - Function on display controlled by the operator to move backFire Irons - Metal po
60Flex Fuel Owner’s Manual 2012 Possible reasons why an ignition fault may be caused: • Theashchamberoruepipeiscoveredinash. • Theas
612012 Flex Fuel Owner’s ManualIf a buer is available, the following gure appears on the screen of the actual values of individual system components
62Flex Fuel Owner’s Manual 2012Release Method You may select 3 dierent types of releases for the buer. Likewise, the release type only has an aect
632012 Flex Fuel Owner’s Manual15: Maintenance15.1 General InformationNote: The Owner/Operator must follow any local and state codes/laws concerningth
64Flex Fuel Owner’s Manual 201215: MaintenanceCleaning the Ash Chamber •Checkthatthefurnaceisnotoperationalandiscool •Opentheouterencl
652012 Flex Fuel Owner’s Manual15: MaintenanceNotes:
66Flex Fuel Owner’s Manual 2012If a malfunction occurs, the error message is directly displayed on the screen.The red LED of the ESC key is switched o
672012 Flex Fuel Owner’s ManualSafety temperature limiter has tripped! The furnace temperature can rise above 194 °F if there is a sudden reduction i
68Flex Fuel Owner’s Manual 2012Burn back damper blocked! The burn back damper could not be fully opened during pellets start. Possible causes of thi
692012 Flex Fuel Owner’s Manual17: TroubleshootingProblem Cause/SolutionHeating system isnot workingFurnace is producingexcessive smokeCheck power con
72012 Flex Fuel Owner’s Manual3: Safety• AllinstallationandoperationsmustfollowSTATEandLOCALCODESforwiring,plumbing,andringofthis
70Flex Fuel Owner’s Manual 201218: SpecicationsFlex fuel 30 kWFlex fuel 60 kWMaximum Current DrawAverage Daily Power ConsumptionMax Heat CapacitiesHo
Customer’s Name ________________________________ Dealer’s Name _____________________________Customer’s Signature _____________________________ Dealer’
Installed by: Dealer CustomerIf customer, was installation explained to you? Yes NoType of Installation: House/Garage Shop/Shed Green
Customer’s Name ________________________________ Dealer’s Name _____________________________Customer’s Signature _____________________________ Dealer’
Installed by: Dealer CustomerIf customer, was installation explained to you? Yes NoType of Installation: House/Garage Shop/Shed Green
752012 Flex Fuel Owner’s ManualWoodMaster FLEX FUEL Warranty NORTHWEST MANUFACTURING, INC. 600 Polk Ave. SW – Red Lake Falls, MN 56750 Toll free (800)
May quality, workmanship and on going product enhancement never be just a passing thought, but rather an everyday tangible aspect, that improves the l
8Flex Fuel Owner’s Manual 20123: SafetyUL Certication
92012 Flex Fuel Owner’s Manual4: Features1. Ash Door - A large opening to make cleaning the ash chamber simple and easy.2. Firebox door - A large open