62
Flex Fuel Owner’s Manual 2012
Release Method
You may select 3 dierent types of releases for the buer. Likewise, the release type only has an aect in
thefurnaceoperatingmodes"Pelletsautomatic",and"Bulkmaterials-automatic".
Always O
If you select always o, the buer is not charged to its required temperature. The buer is maintained
above 50 °F in the freeze protection mode (outside temperature is lower than auto freeze protection
temp. Refer to general heating cycle 1 settings).
Always On
The buer temperature is recharged if the buer temperature top has dropped below the set minimum
buer temperature top.
With Clock
The buer is only recharged within the set release periods, if its buer temperature top has dropped
below the set minimum buer temperature top.
Release Period 1 to 3
You can set 3 dierent release periods for the buer from 0:00 to 24:00 hours. If you do not require all
release period, set the starting and ending value to the same setting value in order to deactivate this
release period.
14: Buer/Thermal Storage